Taking work now — the first look is freeSSDs posted in from anywhere in the UK, or handed in at ten drop-off pointsQuicker still, give us a ring:0800 6890668
SDRSSD Data Recovery 0800 6890668 Price my job
SDR / Every kind of SSD / PCIe add-in cards

HHHL · FHHL · x4, x8 and x16 cards

PCIe add-in card SSD recovery. A drive shaped like a graphics card, and quoted after the free look.

Add-in card SSDs sit in a desktop or server slot. Some are a single enterprise controller on a card, such as Samsung's PM1725-series HHHL cards or Intel's Optane 900P and 905P. Some are carrier cards holding two or four M.2 drives in a software or hardware RAID, and some are older multi-controller designs such as OCZ's RevoDrive. A single-controller card is priced as a single SSD at £300 + VAT; a card that is really a RAID of several drives is a multi-drive set from £500 + VAT. The fixed figure is written down after the free look.

Free first lookOne fixed figure in writingNo data, no bill on most jobsReturn postage paid

Rather talk it through? An engineer answers the bench line
0800 6890668

Add-in card symptoms, and what they mean.

Not listed? Describe it on the form →
Packing it and posting it: a bare SSD travels in an anti-static bag inside a small padded box, with nothing able to move. Insure it for what the files are worth rather than the price of the drive, and use a tracked service. The posting address is not printed anywhere on this site; it arrives by email in reply to the form, with a booking sheet to print; the sheet inside the parcel is what matches it to your enquiry when it is opened. Or hand the sealed parcel in at the nearest of ten drop-off points, your name on the outside and the sheet inside; say where you are on the form and it comes by email. We pay the postage home either way. The whole of it is written up on the guide to packing and posting.

Card by card, and what is possible.

Samsung PM1725, PM1725a, PM1735 HHHLEnterprise controllers on Samsung flash, with power-loss protection. Recovered through the controller; hardware encryption means the original controller is needed.
Intel Optane 900P, 905P, P4800X, P5800X3D XPoint rather than NAND. Intel wound the Optane business down in 2022, so these are legacy and tool support is thin. We say at the free look whether a given card can be taken on.
Carrier cards: ASUS Hyper M.2, Gigabyte AORUS Gen4 AIC, OEM boardsSeveral ordinary M.2 drives on one card, in RAID 0 more often than is wise. Every drive and its slot position are needed.
OCZ RevoDrive and other legacy multi-controller cardsTwo or four SandForce controllers behind an on-card RAID. Imaged member by member and reassembled in software.

What the machine reports, and what it means.

Describe yours to us →
What is going on The usual reason for it Where that leaves you
Nothing in the BIOS or lspciThe card is not enumerating on PCIeController or power work
The RAID volume is degraded or missingA member failed, or the array's metadata didImage every member; rebuild in software
An Optane card reports errorsMedia or controllerAssessed honestly; not every one can be taken
The card works in one machine and not anotherBifurcation or lane settingsCompatibility, not failure

From the box arriving to your files going back.

Work we have closed →
01

Logged the day it lands, and the first look costs nothing Free

A case number goes on it the day the parcel is opened, and an engineer settles what has actually failed before anything else happens. The drive is read on our own equipment, never in a computer that might send it a TRIM command. Back to you come two things together: a straight note of what is liftable and what is not, plus one figure, fixed and written down. Accept it, or decline and owe us nothing.

Nothing to pay for lookingA single figure, put in writingNo TRIM, no writes
02

Powered on our terms

Every power-on gives a failing SSD another chance to run its own housekeeping. Here the drive is brought up in the controller's diagnostic state instead, which lets the bench speak to the flash directly and keeps damaged firmware out of the conversation.

Vendor diagnostic modeNo hopeful reboots
03

Past the fault, to the map

A single-controller card is worked on like any enterprise SSD: diagnostic state, service area, map rebuild, full image. A carrier card is taken apart into its members, each imaged on its own, and the RAID put back together in software from the images and the card's own metadata.

Loader in RAM, never on the flashMapping tables put back together
04

A full image, then the volume

Nothing is worked on live. The whole drive is imaged once, weak pages retried in their own passes, and the file system is put back together on the image. Encrypted volumes are unlocked there too, with the key you supply, and never on the original.

One careful imageThe volume verified end to end
05

You see the file list before you pay

What was recovered is listed for you first, and only then does a bill exist. Approve the list and it is invoiced; turn it down and it is not — and where nothing has come back, most jobs carry no charge at all. Recovered data travels home on fresh media bought in for your job, with the postage at our end. Your case is not closed until you have opened the files on a machine of your own.

No charge until you accept the figureFresh media, supplied with the jobQuoted with the figure

What arrives most often

  • Send the whole card, not just the drives, and tell us the RAID settings if you know them. The card's own metadata often holds the stripe size and order.
  • Optane is not NAND. The routines that work on flash do not apply, and the discontinued line has little tool support. We would rather tell you no at the free look than take a job we cannot finish.
  • A carrier card RAID 0 is only as strong as its weakest stick. One failed M.2 drive takes the whole volume with it until that drive is imaged.
  • Bifurcation settings are a common false alarm. A carrier card that suddenly shows one drive instead of four is often a BIOS setting after an update, not a failure.

One job, followed all the way through.

UK · SDR-2026-0347JOB LOGGED ✓

A four-stick carrier card in RAID 0, with one member gone quiet

A video workstation's scratch and project drive was four 1TB NVMe sticks on a carrier card, striped. One stick stopped enumerating and the volume vanished. Each stick was imaged on its own, the quiet one in the controller's diagnostic state, and the stripe was reassembled in software from the card's metadata. The project files were complete.

100% of the volume rebuilt5 days here, and back by post
Illustrative example — replace with a genuine case

What helps, and what harms.

Do this much first

  • Send the complete card in its anti-static bag
  • Note which slot each M.2 stick occupied if you remove any
  • Tell us the RAID level and stripe size if known
  • Try one other slot before posting, once

What sets us back

  • Rebuilding or re-creating the RAID
  • Removing sticks from a carrier without noting positions
  • Flashing card firmware
  • Assuming an Optane card is unrecoverable before asking

Questions answered before you commit.

Is Optane recoverable?

Case by case. 3D XPoint has little third-party tool support and the line is discontinued. We assess honestly at the free look and only take on what we can finish.

Do I send the card or the drives?

The whole card, with a note of its RAID settings. If sticks have been removed, note which slot each came from.

What does it cost?

A single-controller card is £300 + VAT. A carrier card holding several drives is a multi-drive set from £500 + VAT. The figure is written down after the free look.

How long does it take?

Quoted with the figure; a single card is typically 3–5 days at the bench.

Nothing gets worse while the power is off.

Looking at it is free. Back comes a list of what opened and what did not, together with a single price to finish, set down in writing while you are still free to say no. On most jobs an invoice only follows the data. Until that list reaches you, leave the drive switched off.

0800 6890668